Loading Events

« All Events

[Thesis Defense] : Multi-modal microfluidics: Unification of impedance, deformability and imaging modalities for label-free single cell analysis

November 27 @ 11:00 am - 5:00 pm
Thesis Title : "Multi-modal microfluidics: Unification of impedance, deformability and imaging modalities for label-free single cell analysis"

Name of the Student   : Ms. Ishita Bansal
Degree Registered     : Ph.D. Engineering 
Advisor               : Prof. Prosenjit Sen, CeNSE
Date                   : 27th November 2026 (Friday)
Time                  : 11 AM
Venue                 : IDS G-11 Classroom, (Hybrid)
Abstract:

For more than 20 years, microfluidic impedance cytometry has been a potent label-free technique 
for high-throughput examination of single-cell biophysical characteristics. Cells are forced to 
pass one at a time via micrometre-sized channels that resemble blood vessels. Integrated microelectrodes 
are used to monitor the electrical impedance of the cells while they are in flow. Since biological 
cells exhibit distinct dielectric properties across a wide frequency range, multi-frequency probing 
reveals complex cell phenotypes such as cell volume, cell membrane capacitance and cytoplasmic 
conductivity from low to high frequency range. This approach has allowed researchers to understand 
cell viability, monitor the activation states of cells, identify diseases rapidly, and highlight 
biological heterogeneity within cells without compromising on cellular health. Along with the electrical 
measurements, researchers have explored the integration of mechanical measurements within the same device. 
The mechanical properties of cells have been shown to vary in various health conditions such as malaria 
and diabetes. To study the cell mechanical properties,  cell deforming mechanisms have been added to the 
impedance cytometers, either through forced physical confinement or stretching by fluid forces. 
The transit time of the cell in such stressful conditions reveals its underlying mechanical properties.

Despite these distinct advantages, the true potential of electro-mechanical impedance cytometry remains locked. 
Current microfluidic platforms evaluate cell deformability by placing sensing electrodes before and after squeezing,
 using total transit time as a representation for mechanical property. But this method puts the active process of
 deformation inside a black box, missing the real-time dielectric changes of the cell as it is subjected to maximum physical strain.

To unlock the full potential of label-free diagnostics, this thesis first develops an advanced microfluidic
 architecture featuring specialised electrode topologies actively profiling cells in their native, 
deformed and post-deformation states. This strategy helps measuring cell properties dynamically as they 
flow inside the microchannel and squeeze actively. We demonstrate the different cell parameters this 
design is able to capture and their importance in differentiating between different cell types.

In the next part of the work, we developed a machine learning workflow to capture the maximum number 
of independent features for effective cell classification. A high dimensional dataset was generated, 
trained and tested on both supervised and unsupervised datasets, using the built workflow, reducing 
data dimensionality and isolating the most significant parameters for differentiation between major 
subclasses of blood cells. We demonstrated a complete sample-to-analysis workflow for classifying any new cell sample.

Even with the multi-parametric datasets obtained through electro-mechanical system, purely electrical 
systems lack an independent validation mechanism, i.e., they are incapable of differentiating between 
a genuinely unique cellular phenotype and artifacts caused by rotation of a cell, debris or an aggregate 
of multiple cells. Therefore, for advanced single-cell diagnostics, a multi-modal system is required.

The next part of this thesis focuses on building a stroboscopic imaging platform to image cells in 
flow using a standard camera and an LED pulsing circuit. Having a stroboscopic imaging system eliminates 
the need for expensive, bulky and heavy data generating high-speed cameras. We, first, demonstrate 
two major schemes for pulsing light sources, namely voltage and current-based pulsing. The circuit 
characterisation for both the schemes is then shown which validated the working of the circuits and 
established current pulsing scheme as a better strategy for imaging cells.

In the final part of this work, we developed a system integrating the current pulsing circuit with
 microfluidic device and a standard camera for capturing cell images in flow. We contrast the use of 
continuous and pulsed light illumination on moving cell imaging. The imaging modality is then synchronised 
with the electrical impedance measurement system to image cells, getting triggered only when the cell reaches 
the detection zone, reducing unwanted frames. Integration of imaging modality to the electro-mechanical 
cytometry introduces optical validation synchronously and provides blur-free visual ground truth at high flow speeds.

Details

  • Date: November 27
  • Time:
    11:00 am - 5:00 pm